An excellent choice for most FLOMEC® Meters. Commonly used features are pre-programmed in the display. End-users can enable additional features by using a password available from the factory, or click the button below to find. The 09 configuration provides a high degree of customization, matching customers’ exact needs.
09 Configuration CodeUSER CONFIGURATION
Using a password-protected configuration process you can enable additional features. GPI Customer Service can provide the password and instructions to unlock and reset configuration settings. This information is also available on the GPI website.
User configuration features include:
STANDARD FACTORY CONFIGURATION: | 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and litres; User Calibration and Rate of Flow Indication |
DISPLAY ELECTRONICS: | 09 Electronics can be used on G, G2, TM, A1, and QSE Series Meters |
TOTALIZING REGISTERS: | 0 to 3 available |
K-FACTOR LIMITS: | Min: .01 pulses/unit; Max: 999,999 pulses/unit |
FIELD CALIBRATION: | Field calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry. |
READOUT TOTALS: | LCD with floating decimal: Minimum Display = 0.01 units; Maximum Display = 999,999 x 100 units (6 digits) |
INPUT PULSE RATE: | Minimum (Pulse-in Input) = DC (0 Hz) |
Minimum (Coil Input) = Approximately 10 Hz | |
Maximum = Approximately 1,000 Hz | |
TURBINE DISPLAY: | |
INTERNAL POWER SUPPLY: | 2 Lithium batteries at 3 volts each |
LITHIUM BATTERY LIFE: | 5 Years |
OPTIONAL POWER SUPPLY: | 7 to 30 V (dc) |
OVAL GEAR DISPLAY: | |
INTERNAL POWER SUPPLY: | 9-volt battery |
OPTIONAL POWER SUPPLY: | 10 to 18 V (dc) |
TEMPERATURES: | |
OPERATING TEMPERATURE: | 0° F to +140° F (-18° C to +60° C) |
STORAGE TEMPERATURE: | -40° F to +158° F (-40° C to +70° C) |
A1 & G2 Models ONLY